Skip to content
646 567 732
EspañolEnglish

Air leaks through windows: how to prove them

Filtracion arie ventanas - Air Leaks Through Windows: How to Prove Them

Can air leaks through windows be claimed as construction defects or building defects? How are they measured or proven in court?

To begin with, it is not an acceptable argument on the part of the developer that this is normal and that the windows were installed in accordance with the applicable regulations. Micro-ventilation (the minimal factory-built openings in the joinery that allow ventilation to work, as required by the CTE) must not be confused with significant air leaks occurring while the windows are closed.

In some developments, air leaks through the windows in the bedrooms and living room are widespread, occurring in windy conditions because these are often tall buildings with no other high-rise buildings around them, causing noise (whistling) as the air enters and seeps inside, as well as a loss of comfort and the resulting cost of heating or cooling the home.

In such cases the air seeps in around the perimeter of the windows and through the gap for the roller-shutter strap, and some windows also have insulation problems. This can easily be verified using a lit lighter to see how the flame moves, and a sheet of paper that likewise moves near the window, showing the air coming in (and all of this should be recorded on video).

In addition, checks were carried out using thermal imaging (with a thermal imaging camera, like the ones we use in our expert inspections, which detects cold areas and heat loss) and an exploratory opening was made below the bedroom window of one home, revealing that the thermal insulation only reached a horizontal metal profile, leaving an area of up to 12.5 cm without thermal insulation up to the window opening; the gap had been filled with mortar, a material that does not meet the thermal requirements of an insulating material.

Please note that all of this can perfectly well be claimed if you are within the time limit. Get advice.

Any questions?

Contact

Don’t hesitate to consult us!

Custom budgets.

Paseo de la Castellana 257, 1º Sur, CP 28046, Madrid

LOPD-RGPD-LSSI

Your message will be added to a file for which DPCON RECLAMACIONES JUDICIALES S.L. is responsible. It will be used solely to process your data in order to deal with your request, in accordance with Regulation (EU) 2016/679 (GDPR), Organic Law 15/1999 (LOPD) and Royal Decree 1720/2007 implementing the LOPD, on data protection. Your data will not be disclosed to third parties, except where required by law, and will be kept until you request its erasure. You may at any time exercise your rights of access, rectification, portability and objection and, where applicable, restriction and/or erasure of processing, by writing to dpcon@dpcon.es with your personal details.

Send enquiry

LOPD-RGPD-LSSI

Your message will be added to a file for which DPCON RECLAMACIONES JUDICIALES S.L. is responsible. It will be used solely to process your data in order to deal with your request, in accordance with Regulation (EU) 2016/679 (GDPR), Organic Law 15/1999 (LOPD) and Royal Decree 1720/2007 implementing the LOPD, on data protection. Your data will not be disclosed to third parties, except where required by law, and will be kept until you request its erasure. You may at any time exercise your rights of access, rectification, portability and objection and, where applicable, restriction and/or erasure of processing, by writing to dpcon@dpcon.es with your personal details.